web supervisor

Second Hand Generators

MTU 800 CONT
PRP kVA: 800
LTP kVA: 880
Recommended use: Stand-By
Engine brand: Mtu
Alternator brand: Marelli
Mechanical version: Container 20'
Manufacture year: 2005
SAP code: 593000101 (ex 992001395)
C 850 U
PRP kVA: 850
LTP kVA: 935
Recommended use: Stand-By
Engine brand: Cummins
Alternator brand: Stamford
Mechanical version: Open
Manufacture year: 1989
SAP code: 992001061
IF 1000 U
PRP kVA: 1000
LTP kVA: 1100
Recommended use: Stand-By
Engine brand: Isotta Fraschini
Alternator brand: Marelli
Mechanical version: Open
Manufacture year: 1988
SAP code: 992001707/1
IF 1000 U
PRP kVA: 1000
LTP kVA: 1100
Recommended use: Stand-By
Engine brand: Isotta Fraschini
Alternator brand: Marelli
Mechanical version: Open
Manufacture year: 1988
SAP code: 992001707/2
C 1260 CONT 40'
PRP kVA: 1250
LTP kVA: 1375
Recommended use:
Engine brand: Cummins
Alternator brand: Leroy Somer
Mechanical version: Container 40'
Manufacture year: 2011
SAP code: 801001210
C1260 CONT 40'
PRP kVA: 1264
LTP kVA: 1390
Recommended use: Continuous service
Engine brand: Cummins
Alternator brand: Leroy Somer
Mechanical version: Container 40'
Manufacture year: 1990
SAP code: 801001362 (ex507551000)
C 1300 U Hitzin.
PRP kVA: 1300
LTP kVA: 1430
Recommended use: Stand-By
Engine brand: Cummins
Alternator brand: Hitzinger
Mechanical version: Open
Manufacture year: 1994
SAP code: 992001130
C 1300 Cont
PRP kVA: 1300
LTP kVA: 1430
Recommended use: Stand-By
Engine brand: Cummins
Alternator brand: Leroy Somer
Mechanical version: Container 40'
Manufacture year: 1995
SAP code: 992001466
C 1325 U
PRP kVA: 1325
LTP kVA: 1457
Recommended use: Stand-By
Engine brand: Cummins
Alternator brand: Leroy Somer
Mechanical version: Open
Manufacture year: 1993
SAP code: 992001126
C 1325 CONT 40'
PRP kVA: 1325
LTP kVA: 1457
Recommended use: Stand-By
Engine brand: Cummins
Alternator brand: Leroy Somer
Mechanical version: Container 40'
Manufacture year: 1987
SAP code: 801001361 (ex 507551001)

Star

With star the start of each of the three phases is connected together. Connections are taken from the ends of the three phases to give the three phases
Star symbol voltage

Delta

With Delta the starts and ends of the phases are connected. The end of phase 1 is connected to the start of phase 2, the end of phase 2 to the start of phase 3, and the end of phase 3 to the start of phase 1. Connections are taken from the three start-end points to give the three phases.
Delta symbol voltage