POWERFULL - P 9 B

Characteristics

110000000201-000-00.jpg
1- Industrial diesel engine in genset version with certificate of origin
2- Industrial brushless alternator with AVR
3- Large capacity steel baseframe-fuel tank with level sensor
4- Industrial silencer and coupling flange
5- Electrical panel mounted on board the unit with digital control device installed in metal box
6- Compact for easy handling and use
7- Test report, manuals and electrical drawings supplied
8- World wide after sales service and technical support
Further details on the technical data sheet
Standard genset technical data sheet
IT EN DE FR RU ES
Standard control panel technical datasheet
ITENFRDERUES
Gen Set performance
9.0
kVA
7.2
kW
9.9
kVA
7.9
kW
0.8
50
Hz
230
V
Dimensions and noise level
960
mm
1420
mm
1114
mm
410
kg

Technical datasheet

Engine
General engine data
PERKINS
403A-11G1
3
1500
r.p.m.
1.13
l
Aspirated
12
Vdc
Vdc
5-6½
0
kPa
Water
Engine power
8.4
kW
9.2
kW
Fuel consumption
2.9
l/h
2.6
l/h
2.0
l/h
1.5
l/h
0.0
l/h
Speed regulation
On request
Engine dimensions and liquids
4.9
l
3.3
l
1.9
l
5.2
l
Heat from engine
8.3
kW
7.3
kW
2.1
kW
Heat from exhaust
368
°C
26.40
m³/min
0.70
m³/min
1.66
m³/min
Emissions
Not available
Not available
Not available
Not available
Alternator
General alternator data
STAMFORD
PI044G
9.9
kVA
9.0
kVA
Alternator wirings
Series double delta
1PH
12 terminals Winding 311
12
nr.
Alternator protection
23
Alternator regulator
AS480
1.0
± %
Baseframe - Canopy - Exhaust muffler
Baseframe data
T1
T1
160
l
0
l
0
l
Canopy & Exhaust muffler
MS 10
48.0
mm
DN40
48.0
mm
Guard revolution control panel
Advanced single gen-set controller for stand-by and prime power applications. Direct communication with EFI engines, total remote monitoring and control, easy to install, configure and use, wide range of communication capabilities including: connection via RS232, RS485, CAN and on board USB, internet access using Ethernet, GPRS or 4G support for Modbus and SNMP protocols. Internal PLC support with PLC editor and monitor included in LiteEdit, cloud-based monitoring and control via Onis Visa WebSupervisor, active SMS and emails in different languages, SNMP traps, geofencing and tracking via Onis Visa WebSupervisor, 2x 10 A binary outputs for cranking and fuel solenoid, option for up to 16 additional binary inputs/outputs, flexible event based history with up to 350 events, load shedding, dummy load capability, tier 4 final support, automatic temperature based cooling/heating, comprehensive gen-set protections, multipurpose flexible timers, true RMS measurement.
GUARD REVOLUTION AUTO
S200B40
110000000265-000-00.png

Accessories

Guard touch control panel
Guard Touch MANUAL OR AUTOMATIC is the new revolutionary controller with touch screen, researched and developed by Visa S.p.A., which will be standard supply on our gensets. From a technical and operational viewpoint, the new device is different from its predecessors, but still maintains Visa’s main characteristic: MODULARITY! Guard Touch is a versatile controller able to satisfy the myriad of requests from the end-user, from manual function to totally automatic management.
GUARD TOUCH AUTO
S200B40
110000000140-000-00.png
ATS changeover switch panel
ATS-C 72
110000000142-000-00.png
ATS is a new line of changeover switch panels developed and manufactured by Visa S.P.A. in accordance with CEI EN 61439-2 (construction standard). Specifically used for generating sets, the changeover switch panel allows the changeover between mains/genset or genset/genset. The main part of the panel contains two interlocking contactors or a motorised circuit breaker. All of the parts are installed inside a sturdy powder-coated metal box (RAL7035) and equipped with a lock to close the access door.

Star

With star the start of each of the three phases is connected together. Connections are taken from the ends of the three phases to give the three phases
Star symbol voltage

Delta

With Delta the starts and ends of the phases are connected. The end of phase 1 is connected to the start of phase 2, the end of phase 2 to the start of phase 3, and the end of phase 3 to the start of phase 1. Connections are taken from the three start-end points to give the three phases.
Delta symbol voltage