MAIN DATA

Continuous power (PRP)
1900.00
kVA
Continuous power (PRP)
1520.00
kW
Stand-by power (LTP)
2035.00
kVA
Stand-by power (LTP)
1628.00
kW
Power factor 0.8 cos(fi)
Frequency (Hz) 50 Hz
Voltage (V) 400 VAC

DIMENSIONS AND NOISE

AWESOME FEATURES

1- Industrial diesel engine in genset version with certificate of origin
2- Industrial brushless alternator with AVR
3- Steel baseframe
4- Soundproof container
5- Exhaust silencer with insulated manifold
6- Electrical panel mounted on board the unit with digital control device installed in metal box
7- Test report, manuals and electrical drawings supplied
8- World wide after sales service and technical support
Further details on the technical data sheet

TECHNICAL DATA

GEN SET GENERAL DATA
Genset model M 1900 CO
Connection Star
DIMENSIONS AND NOISE
ENGINE BASE DATA
Description MITSUBISHI
Engine model S16R-PTA2
P.R.P. Power 1900.0 kVA
L.T.P. Power 2090.0 kVA
Cylinders 16.0
Speed 1500.0 r.p.m.
Cubic capacity 65.4 l
Air intake Turbocharged
Standard voltage 24.0 Vdc
Optional voltage Vdc
Sae 00-21
BMEP 1991.0 kPa
Cooling Water
Fuel Cons. at 100% (L.T.P.) 448.0 l/h
Fuel Cons. at 100% (P.R.P) 396.0 l/h
Fuel Cons. at 75% (P.R.P.) 305.0 l/h
Fuel Cons. at 50% (P.R.P.) 220.0 l/h
Fuel Cons. at 25% (P.R.P.) 125.0 l/h
EMISSIONS
TA Luft Not available
TA Luft/2 Not available
EPA Not available
Stage Not available
SPEED REGULATION
Electronic regulator Standard
Precision class G3
ENGINE DIMENSIONS AND LIQUIDS
Oil quantity 230.0 l
Engine Antifreeze capacity 170.0 l
Radiator antifreeze capacity 144.0 l
Total amount of antifreeze 314 l
HEAT FROM ENGINE
Heat from radiator 945.0 kW
Heat from exhaust 1093.0 kW
Heat from radiation 113.0 kW
HEAT FROM EXHAUST
Exhaust temperature 0.0 °C
Combustion air flow 130.0 m³/min
Exhaust gas flow 343.0 m³/min
GENERAL ALTERNATOR DATA
Description STAMFORD
Alternator model PI734E
L.T.P. Power 2035 kVA
P.R.P. Power 1900 kVA
ALTERNATOR WIRINGS
Connection Star
Phases 3F+N
Winding 6 terminals winding 312
Terminal Number 6 nr.
ALTERNATOR PROTECTION
IP Protection 23
ALTERNATOR REGULATOR
Electronic regulator MX341
Precision 1 ± %
RADIATOR
Radiator antifreeze capacity 144 l
BASEFRAME DATA
Model ST60
Standard tank 0 l
CANOPY DATA
Canopy model CONTAINER 40 FT HIGH CUBE
Silencer model ----
Silencer outlet diameter 0 mm

STANDARD CONTROL PANEL

Advanced single gen-set controller for stand-by and prime power applications. Direct communication with EFI engines, total remote monitoring and control, easy to install, configure and use, wide range of communication capabilities including: connection via RS232, RS485, CAN and on board USB, internet access using Ethernet, GPRS or 4G support for Modbus and SNMP protocols. Internal PLC support with PLC editor and monitor included in LiteEdit, cloud-based monitoring and control via Onis Visa WebSupervisor, active SMS and emails in different languages, SNMP traps, geofencing and tracking via Onis Visa WebSupervisor, 2x 10 A binary outputs for cranking and fuel solenoid, option for up to 16 additional binary inputs/outputs, flexible event based history with up to 350 events, load shedding, dummy load capability, tier 4 final support, automatic temperature based cooling/heating, comprehensive gen-set protections, multipurpose flexible timers, true RMS measurement.
CONTROL PANEL DATA
Description GUARD REVOLUTION AUTO

STANDARD ATS

ATS PANEL DATA
Description ATS-M 3150